DR6000 UV VIS Spectrophotometer with RFID Technology HACH USA

Call: 01715 130348

DR6000 UV VIS Spectrophotometer with RFID Technology 

Model: DR 6000

Brand: HACH

Country of Origin: USA

Description

DR6000 UV VIS Spectrophotometer with RFID Technology HACH USA

 

Experience Superior Performance with the DR6000 UV VIS Spectrophotometer, the industry’s most advanced lab spectrophotometer.

Designed for professional laboratories, it’s features support lab managers in calibration routines, quality assurance, and the development of customized applications. This advanced UV-VIS spectrophotometer offers high-speed wavelength scanning across the UV (ultraviolet) and Visible Spectrum and comes with 250 pre-programmed Hach methods to meet all your water quality analysis needs, including regulatory compliance.

Optional accessories for the UV-VIS spectrophotometer include a carousel for different path length sample cells and a sample delivery system that eliminates optical difference errors, ensuring increased accuracy. This UV-Vis spectrophotometer is perfect for handling a wide range of water testing needs.

When you combine the DR6000 UV-VIS spectrophotometer with Hach’s unique TNTplus reagent vial system, you gain additional accuracy and error protection. RFID technology in both the DR6000 and TNTplus reagents automatically notify you if your TNTplus reagents have expired, automatically select the correct pre-programmed method and reduce variations. Hach’s Truecal software comes standard in today’s DR6000’s which reduces variations in results caused by variances in chemistry raw materials

 

This instrument connects to Claros, Hach’s innovative Water Intelligence System, enabling you to seamlessly connect and manage instruments, data, and process – anywhere, anytime. The result is greater confidence in your data and improved efficiency in your operations. To unlock the full potential of Claros, insist on Claros Enabled instruments.

Benefits

Your Water Testing Needs, All in One Spectrophotometer

The DR6000 has the most pre-programmed testing methods, including high-speed wavelength scanning across the UV and Visible Spectrum.

Accessories for High Volume and High Accuracy Testing Needs

A carousel sample changer allows up to seven sequential measurements. The Sipper Module, an instrument-controlled sample delivery system, increases precision by constant optical characteristics.

Advanced Quality Assurance at Your Fingertips

The DR6000 comes with integrated QA software for scheduling, documenting and interpreting all of your needed quality measurements.

Guided Procedures and Elimination of False Readings

The DR6000, when used with TNTplus® reagent vials, provides the accurate results you need by guiding you step-by-step through your testing procedures. With TNTplus, the instrument averages 10 readings and eliminates outliers, making scratched, flawed or dirty glassware a non-issue.

Automatically Avoids Errors

RFID* technology automatically updates the program calibration factors when you place a TNTplus reagent box near the DR6000. The instrument identifies chemistry expiration dates via a barcode on the vials, and detects chemistry coefficient factors to avoid errors that can occur in lot-to-lot variations in the chemistry.
*RFID technology currently available only in US, Anguilla, American Samoa, Australia, Bolivia, Canada, Cayman Islands, Columbia, Dominican Republic, El Salvador, Federated States of Micronesia, Guam, Guatemala, Marshall Islands, New Zealand, Northern Mariana Islands, Palau, Panama, Puerto Rico, and US Virgin Islands.

Specifications

Technical Attributes
Data Logger 5000 data points (result, date, time, sample-ID, user-ID)
Display TFT 7 inch WVGA color touch
Enclosure Rating IP20 with closed lid
Interfaces USB type A (2), USB type B, Ethernet, RFID module
Manual Languages en, es, fr, ja, ko, pt, zh
Operating Conditions 10 – 40 °C (50 – 104 °F), max. 80% relative humidity (non-condensing)
Operating Mode Transmittance (%), absorbance and concentration (wavelength, time)
Optical System Reference beam, spectral
Photometric Accuracy 5 mAbs @ 0.0 – 0.5 Abs
<1% @ 0.5 – 2.0 Abs @ 546 nm
Photometric Linearity < 0.5 % – 2 Abs
Photometric Linearity 2 1 % at > 2 Abs with neutral glass at 546 nm
Photometric Measuring Range ± 3 Abs
Power Requirements 100 – 240 V; 50/60 Hz
Power Requirements (Hz) 50/60 Hz
Power Requirements (Voltage) 110 – 240 VAC
Preprogrammed Methods > 240
Sample Cell Compatibility Rectangular: 10, 20, 30, 50 mm, 1 inch; round: 13 mm, 16 mm, 1 inch

Optional 100 mm rectangular cell with additional adapter

Scanning Speed 900 nm/min (in 1 nm steps)
Source Lamp Tungsten (visible range), deuterium (UV range)
Specific Technology RFID for easy method update, sample ID and Certificate of Analysis
Spectral Bandwidth 2 nm
Storage Conditions -25 – 60 °C (-13 – 140 °F), max. 80% relative humidity (non-condensing)
Stray Light KI-solution at 220 nm < 3.3 Abs/ < 0.05%
User Interface Languages bg, cn, cz, da, en, es, fr, gr, hr, hu, it, jp, kr, nl, pl, pt, ro, ru, sl, sl, sv, tr
User Programs 200
Warranty 12 months
Wavelength Accuracy ± 1 nm
Wavelength Range 190 – 1100 nm
Wavelength Reproducibility < 0.1
Wavelength Resolution 0.1
Wavelength Selection Automatic, based on method selection
Weight 11 kg (24.3 lbs)
What’s included? 1x DR6000 UV VIS Spectrophotometer
1x Power Cord (US, EU)
1x Universal-Adapter
1x Dust Cover
Matched pair of 1 inch glass sample cells
Printed multilingual basic user manual (en, fr, es, pt, zh, jp, ko)

Brand