Description
Dry Heat Sterilizer 48L Model: JSOF-050S JSR Korea
JSOF-Series Dry Heat Sterilizer is a common instrument to be used to drying, heating and sterilizing objects by heating air up to +160 oC or +180 oC with forced convection system during specified sterilizing exposure time range from 30 to 60 minutes.
MAIN FEATURES
PERFORMANCE
-Forced air convection for fast heat up and even thermal distribution
-Separate heating compartment prevents contamination and maintenance free
-50mm thick high thermal efficiency mineral wool with woven aluminum barrier sheet saves energy and less dust
CONSTRUCTION
-Durable epoxy powder coated metallic casing
-Ventilation damper
-Corrosion resistant Stainless Steel 304 chamber with seamless round cornered edge allows easy cleaning and prevent leakage
CONTROLLER
-JSC-0D Digital PID Controller
-±0.1 oC Digital PID Controller with LED Display
-Automatic START/STOP timer
-Adjustable timer scale 99min 59sec / 99hr 59min / 99 day 23hr or continuous operation
-Temperature calibration
-Auto-tuning function
-Class A Pt-100Ω sensor
CONVENIENCE
-Stainless Steel 304 Chamber with seamless round cornered edge allows easy cleaning and prevents leakage
-Removable and height adjustable shelf by 25mm spacing
-Easy to open and air-tight one touch door latch
-Opening size adjustable ventilation damper
-Door switch cut-off heater and/or blower
SAFETY
-DUAL OVER TEMP. CUT-OFF
Digital system cut-off heater and AUDIO VISUAL ALARM in case +2 oC above set temperature Analog system cut-off heater 10% above set temp.
-MAX TEMP CUT-OFF heater and AUDIO VISUAL ALARM when +1 oC above maximum limit
-DOOR SENSOR cut-off heater and blower when door opened
-SENSOR DISCONNECTION ALARM
-OVER CURRENT CUT-OFF : Electrical Leakage Breaker
SPECIFICATIONS
DESCRIPTIONS MODEL JSOF-050S
Dimension Data
Chamber Volume 48 Liters
Inner Dims. (W x D x H mm) 400 x 300 x 400
Outer Dims. (W x D x H mm) 560 x 585 x 710
No. of Shelf included 2 ea
No. of Shelf Position 12 ea by 25mm spacing
No. of Ventilation Damper 1 ea
Performance Data
Heating System Forced Air Convection
Temp. Range Amb. +10 oC ~ +250 oC
Accuracy at 180 oC ±0.2 oC
Uniformity at 180 oC ±1.0 oC
Heat up time to 180 oC 15 min.
Controller
Processor Digital Microprocessor PID Temperature Controller
Display 4 Digit LED Display
Temp. Calibration Built-in Temperature Calibration Auto-tuning
Temp. Resolution 0.1 oC
Timer Scale 99 min 59 sec / 99 hr 59 min / 99 dy 23 hr
Turn-On Delay Time Automatic START/STOP timer / Continuous Operation
Sensor CLASS A PT-100 Ω Sensor
Safety Data
Safety Device DUAL OVER TEMP. CUT-OFF
Digital system cut-off heater and AUDIO VISUAL ALARM Analog system cut-off heater 10% above set temp.
MAX TEMP CUT-OFF heater and AUDIO VISUAL ALARM
CUT-OFF heater and blower when door opened SENSOR DISCONNECTION ALARM
Over Current CUT-OFF
Material Data
Body Epoxy Powder Coated Steel
Chamber Stainless Steel 304, 0.8 mm thickness
Insulation 50 mm Woven Mineral Wool
Electrical Data
Rated voltage 220 ± 10% VAC
Power frequency 50 / 60Hz
Heater Output 1.0 kW
Nominal power 1.0 kW 4.7 amp
Phase 1 Phase
Plug configuration CEE 7/7 Schuko or BS 1363
Usable Condition
Temp. & Humidity 5oC – 40 oC, < 80% RH
Packaging Data
Type of packaging Carton on a wooden palette Shipping Dims. (W x D x H mm ) 640 x 590 x 840 mm
Net Weight 48.0 kg
Shipping Weight 57.0 kg
ORDERING INFORMATION
| Art. No. | Descriptions | Voltage |
| JSOF-050S | Dry Heat Sterilizer, 48 L | 220 VAC 1~ ph 50/60Hz |
| including standard accessories | ||
| 2 ea x Wire Shelf, Stainless Steel 304 | ||
| 8 ea x Shelf Support | ||
| 1 ea x Instruction Manual | ||
| 1 ea x Warranty Certificate |
OPTIONAL ACCESSORIES
Art. No. Descriptions
PHS-A03 Perforated Shelf, Stainless Steel 304, W370 x D280 mm
PHS-B03 Wire Shelf, Stainless Steel 304, W370 x D280 mm
PHS-A99 Shelf Support, Set of 4 ea