COD Thermoreactor Model: CR 4200
Digestions with 2×12 round cells at 2 different programs :
With CR 4200 two different digestion programs can be performed for 16 mm vials simultaneously in two seperate heating blocks for 12 vials each.
• 8 stored programs for quick operation
• 8 user-defined programs from 25-170°C for high temperature digestion up to 170°C
• AQA/IQC with external temperature sensor
Standard digestion programs for the standard parameters COD, quick COD (148°C, 20 min.), total nitrogen, total phosphorus, TOC and heavy metals of galvanizing with automatic heating and switch-off. 8 user-defined digestions at temperatures between 25-170°C can be programmed for special digestions allowing also high temperature digestions.
Two different programs for 12 cuvettes each can be run at the same time (CR 3200 offers the smaller solution with 2×12 cuvette at one program at a time). You can use an external temperature sensor instead of a vial with data output to the PC/printer for analytical quality assurance (AQA).
Programs for standard parameters :
• 1: 148 °C for 120 minutes
• 2: 120 °C for 30 minutes
• 3: 120 °C for 60 minutes
• 4: 120 °C for 120 minutes
• 5: 100 °C for 60 minutes
• 6: 148 °C for 20 minutes
• 7: 150 °C for 120 minutes
• 8: 100 °C for 30 minutes
Specification:
Reactor type | Dry temperature control device with safety cover |
Cell shafts | 2 x 12 cell shafts for reaction cells, diameter: 16 ± 0.2 mm |
Reaction time setting | program settings or user-defined programs up to 180 min |
Temperature setting | stored program, user-defined settings from room temperature up to 170°C |
Controlling accuracy | ± 1 °C ± 1 digit |
Temperature stability | ± 0.5 K |
Overtemperature protection | 190 °C ± 5 °C |
Dimensions | D x W x H: 312 x 255 x 185 mm |
Weight: | 4 kg |
Output | unidirectional RS232 interface with 2 banana sockets for external temperature sensor (article-# 250 100), printer, PC |
Power supply | 115/230 VAC 50/60 Hz switchable via fuse setting |
allowed voltage tolerance: ±15 % maximum power consumption: 560 W, Fuse 2×6.3 AT | |
Protection Class | IP 20 according to EN 60529 |
Ambient temperature | Operation +5 °C to +40 °C |
Climatic class | 2 according to VDI/VDE 3540 |
Relative humidity: Yearly mean: < 75 % | |
30 days /year: 95 % Other days: 85 % Light dew: yes | |
Site altitude: max. 5000 m above sea level | |
EMC | EN 61326-1 |
FCC 47 CFR Part 15 | |
Test certificates | cETLus, CE |
Safety standards | EN 61010-1 |
EN 61010-2-010 | |
UL 61010-1 | |
CAN/CSA C22.2#61010-1 | |
CAN/CSA C22.2#61010-2-010 |